Product Introduction
A building steel structure is judged first by how the loads move through it. Roof panels, purlins, rafters, columns and base plates form one continuous path from the roof surface down to the foundation, and each member in that path is sized for the force it actually receives. The frame we detail does not start from a standard section list; it starts from the loads at the site and the reactions those loads produce.
Our engineers run the model in SAP2000, AutoCAD, PKPM, 3D3S and Tekla together. The dead weight of the roof and walls, snow on the roof, wind on the walls, seismic action and any crane or equipment load are entered as site-specific values, and the model returns member forces, deflections and base reactions. Those reactions are what your civil contractor needs for the foundation, and they are issued in the drawing set rather than estimated on site.

Product Specification
|
Items |
Specification |
|
|
Main Steel Frame |
Column |
Q235,Q355 Welded H Section Steel |
|
Beam |
Q235,Q355 Welded H Section Steel |
|
|
Secondary Frame |
Purlin |
Q235 C and Z purlin |
|
Bracing |
Q235 Round Bar,Angle Steel,Steel Pipe |
|
|
Roof and wall |
Insulation |
EPS/Fiber glass wool/Rock wool/PU |
|
Sheeting |
PPGI single Sheet |
|
|
Accessories |
Windows |
Aluminum Alloy /PVC Window,etc. |
|
Doors |
Sliding/swing sandwich panel door/Roll-up Door |
|
|
Draining system |
Stainless/PPGI single sheet gutter+ PVC pipe |
|
|
Loading requirements |
As customized |
|
|
Earthquake-resistance |
9 Grades |
|
|
Life time |
Up to 50 years |
|
|
Anti-rust options |
Anti-rust painting(Alkyd/Epoxy) or Galvanized |
|
Load Path From Roof Sheeting to Foundation
The path starts at the roof surface. Snow, rain and the weight of the panels themselves land on the roof sheeting, which spans between purlins; the purlins carry that load to the rafters; the rafters transfer it to the columns; the columns pass the axial force and bending moment down to the base plate; the base plate spreads the load to the anchor bolts and the foundation. Each step in that chain has to close: a purlin that deflects under snow, or a rafter that slips its bearing, leaves the member below carrying more than it was sized for.
Wind works the other way on parts of the frame. On the windward wall it pushes inward; on the leeward side it can pull outward, and suction on the roof can lift rather than press. The frame is checked for these tension and uplift cases alongside the downward loads, so base plates, hold-down bolts and connections are sized for the reaction that may pull up, not only for the weight pressing down. Seismic action adds lateral force that the columns and the bracing system have to resist, and the model combines the load cases the relevant code requires.
The path ends at the foundation interface. We issue the column reaction - axial, shear and moment - and the base plate and anchor detail for each column position. Your civil contractor designs the footing from those numbers; we do not guess the foundation size from a catalogue building. Where the site has weak soil or a high water table, the reaction set is what tells the civil side whether a pad, strip or pile foundation is needed.

Member Selection: Sections, Grades and Connections
Rafters and columns are welded H-sections chosen from the bending diagram. The depth follows the span and the moment at midspan and at the eaves; the flange width and web thickness follow the shear and the lateral-torsional buckling check. A rafter that looks heavy in the drawing usually means the span or the snow load asked for it; a section kept slim means the load cases left room for it. We record the section, grade and the controlling load case on the member drawing, so the calculation behind the size is traceable.
Steel grade follows the force, not a default. Q235B covers lighter columns, short spans and low roof loads where the section would otherwise be over-specified; Q355B is used where deeper sections, taller columns or heavier crane reactions demand the higher yield strength. Mixing grades across the frame is normal - main rafters and columns may carry Q355B, purlins and secondary members stay on Q235B or galvanized section - and the mill certificate for each grade travels with the shipment.
Connections decide how the frame behaves on site. Main H-sections are welded in the shop under controlled conditions by certified welders to AWS D1.1; the field joints are bolted end-plate connections, so erection does not require welding on site. Purlins connect with cleats and bolts, sag rods tie the purlins against sag, and fly bracing and column bracing provide lateral stability. The joint drawing shows the bolt grade, the end plate thickness and the weld size, and the trial assembly at the plant proves the connection closes before the frame ships.
Why It's Better Than Traditional Construction
Traditional concrete construction demands lengthy curing periods, extensive formwork, and large on-site labor crews. A Building Steel Structure arrives as a precision kit that bolts together, typically cutting calendar time by half and reducing total installed cost by 20–30% . Steel's superior strength-to-weight ratio means smaller foundations, less concrete volume, and reduced soil bearing requirements . Unlike rigid concrete frames, steel structures accommodate future modifications-wall relocations, crane additions, height extensions-without structural compromise . The controlled factory environment ensures consistent material quality, documented weld integrity, and dimensional accuracy that site-cast concrete cannot guarantee
Why Choose Qingdao Ruigang Heavy Industry Co., Ltd.?
We provide comprehensive management and one-stop services covering design, manufacturing, surface treatment, and logistics. Drawing on extensive project experience across more than 70 countries, our products are engineered to meet diverse seismic requirements, wind load specifications, and local building codes. We strictly adhere to ISO 9001 quality standards, implementing rigorous inspections that include material testing, weld checks, dimensional verification, and coating analysis. Furthermore, we provide detailed assembly documentation, video guides, and remote technical support; our expert engineers offer ongoing assistance-both during and after the warranty period-to fully safeguard your long-term interests.
FAQ